7.3.3. Check of the relay of candles of an incandescence

 PERFORMANCE ORDER

  1. Disconnect the incandescence relay. The relay is in a foot well of the forward passenger, behind a cover of a rack And.

Location of the relay of an incandescence

  1. Connect the voltmeter to the plug 30 of the holder of the relay and weight. The voltmeter has to fix presence of tension, otherwise check giving of tension from the battery.
  2. Connect the voltmeter to the plug 86 of the holder of the relay and weight. Include ignition. The voltmeter has to fix presence of tension, otherwise check giving of tension from the battery.
  3. If tension is present, check the wire going to glow plugs and if necessary replace it. Otherwise replace the relay of candles of an incandescence.
  4. By means of an ohmmeter be convinced of lack of resistance between relay plugs 30 and 87. If on plugs 86 and 85 to give tension of the battery, the relay has to turn on. Resistance between plugs 30 and 87 in this case has to be equal to zero.