4.4.3. Removal and installation of a cover of the GRM drive

Removal

Top section

 PERFORMANCE ORDER

  1. Remove the air cleaner (see the Head of the Power supply system, release and decrease in toxicity of the fulfilled gases).
  2. Turn out fixing screws and remove the top section of a cover of a gas-distributing belt.

Top and lower sections of a cover of the GRM drive

Lower section

 PERFORMANCE ORDER

  1. Remove the top section of a cover.
  2. Remove a pulley of a bent shaft (see the Section Removal and installation of a pulley of a bent shaft).
  3. Turn out fixing bolts and remove the lower section of a cover from the engine (address an illustration).

Back cover

 PERFORMANCE ORDER

  1. Remove a gas-distributing belt, its natyazhitel and cogwheels of the GRM drive (see the Sections Removal and installation of a belt of the GRM drive and Removal and installation of cogwheels of the GRM drive).
  2. Release from clamps on a cover an electrical wiring of the sensor of provision of a bent shaft (CKP), - try to remember a route of its laying.
  3. Turn out fixing bolts and remove a back cover from the engine.

Screws of fastening of a back cover of the GRM drive

Installation

Installation is made as it should be, the return to an order of dismantle of components. Track correctness of laying and reliability of fixing of an electrical wiring of the CKP sensor. At installation of a pulley of a bent shaft do not forget to replace a bolt of its fastening. Tighten all fixture with the required effort.